10.2.2 Setting the ignition electrode

- Check the setting of the ignition electrode. Set the gap between the
ignition electrodes: 3 to 4 mm.

10.2.3 Checking the hydraulic pressure

The hydraulic pressure must be a minimum of:
- 0.3 bar for Gas 110 Eco 65,
- 0.5 bar for Gas 110 Eco 115.

10.2.4 Checking the ionization current

Check ionisation level, minimum 4 µA dc (ionisation measurement in
Volts between terminal 4 and earthing, 1 V dc
level < 2µA dc or not present, check:
- Is flame shape stable and colour as described in commissioning
instructions
- Check ignition probe earthing
- Check or replace ignition probe.