7.5.1

Replacing the ionisation/ignition electrode

Fig.51
Replacing the ionisation/ignition
electrode
3
2
1
7.5.2

Cleaning the condensate collector

Fig.52
Open the clicker on the flue gas
pipe
2
1
Fig.53
Remove flue gas pipe
4
7703943 - v.06 - 13122021
4
AD-0000088-01
3
AD-4000128-02
5
AD-4000129-02
The ionisation/ignition electrode must be replaced if:
The ionisation current is < 4 µA.
The electrode is damaged or worn.
The electrode is included in the service kit.
1. Remove the plug of the electrode from the ignition transformer.
Important
The ignition cable is fixed to the electrode and therefore may not
be removed.
2. Remove the two screws.
3. Remove the entire component.
4. Fit the new ionisation/ignition electrode.
5. Reassemble the unit in the reverse order.
To clean the condensate collector, the internal flue gas pipe must be
removed first. Proceed as follows:
1. Remove the return sensor connector.
2. Remove the flue gas temperature sensor (if connected)
3. Open the clicker on the flue gas pipe.
4. Push the upper part of the telescopic flue gas pipe down as far as
possible.
5. Pull up the flue gas pipe and remove it.
7 Maintenance