Main Electrical Supply Connection - Meiko K-200 Owner's Installation, Operation And Maintenance Manual

K-tronic series high temperature sanitizing rack conveyor dishwashers (usa version)
Hide thumbs Also See for K-200:
Table of Contents

Advertisement

S
3 - I
ECTION
NSTALLATION

3.7 Main Electrical Supply Connection

WARNING!
Check that the circuit breaker/fused
disconnect is in the OFF position and
that the unit is switched off before
making the electrical utility connections.
IMPORTANT
In some cases, local codes dictate that
electrical supply connections be made only
by a certified professional.
1. Refer to Figure 3-7. Determine the
locations of the electrical terminal blocks
as follows:
All steam-heated machines use a
single terminal block inside the control
compartment.
Remove top
access panel to
route electrical
supply
Unload
End
K-200 or K-400 series
with steam heat
Terminal
block
Page 10
Figure 3-7: Electrical connections
Electric heat:
Terminal blocks 1-3
Steam heat:
Terminal block
Route from
ABOVE machine.
Remove lower front
BELOW machine.
K-200 series with
electric heat,
no blower dryer
Terminal
Terminal
blocks 1-3
blocks 1-3
Electrically-heated machines have
either 3 or 4 terminal blocks. Terminal
Blocks 1-3 are located inside the
control compartment.
K-200 electrically-heated machines
that are NOT equipped with a blower
dryer use only these three terminal blocks.
K-200 electrically-heated machines
that are equipped with a blower dryer
have a fourth terminal block (Terminal
Block 4) located inside a secondary
electrical box underneath the blower dryer.
All K-400 electrically-heated machines
have a fourth terminal block (Terminal
Block 4) located inside a secondary
electrical box on top of the wash tank.
K-400 Series
electric heat:
Terminal block 4
Route from
ABOVE machine.
K-200 Series
electric heat with
blower dryer:
Terminal block 4.
panel for access.
Route from
K-200 series with
electric heat,
with blower dryer
Terminal
block 4
Load
End
K-400 series with
electric heat
Terminal
blocks 1-3
Terminal
block 4

Hide quick links: