4.2 Startup

Check the level of the external detergent and
rinse aid dispensers. If necessary, replace or
refill the dispensers.
Check that the wash arm manifolds, scrap
screens, curtains, and all other removable
components are correctly installed in the
machine.
Check that the front access door(s) are
closed.
Switch the master circuit breaker/fused
disconnect to the ON position.
Check that the drain handles are in the DRAIN
CLOSED position.
Press the POWER ON button. The
light above the button will begin to
flash.
The machine will begin to
fill. When the LCD display
shows "Ready for opera-
tion," and the light above the POWER ON
button stops flashing and stays on, the tanks
are filled and heated.
WT1 = Wash Tank 1
WT2 = Wash Tank 2 (K-400 Series only)
PAR = Pumped Auxiliary Rinse zone
FR = Final Rinse zone
Page 20
IMPORTANT
Note that while the tanks are heated, the final
sanitizing rinse (FR) has not yet heated to
the correct temperature (180°F minimum).
Press the START OPERATION
button to start the wash pumps. The
light above the button will illuminate.
As the water circulates through the machine,
the final rinse water will begin to heat to the
correct temperature.
The wash pumps will
operate for one rack cycle
(usually 1-2 minutes).
When the wash pumps stop, check the final
rinse temperature (FR). If the temperature has
not reached 180°F, load an empty rack into
the machine. Water will again circulate
through the machine and the final rinse
temperature will continue to rise.
When the final rinse (FR)
has heated to 180°F, wait
for the wash pumps to
stop operating. The
display will read "Cycle
Pause" instead of "Ready
for Operation."
Racks can now be loaded into the machine
for washing.