2. Check that the incoming power leads are
of sufficient rating for the appliance's
current draw. Amperage and minimum
supply wire specifications are shown on
the wiring diagram, the serial plate and
the electrical information label(s) next to
each terminal block.
3. Remove the top access panel from the
control compartment as shown in Figure 3-7.
4. Fit seal-tight fittings or strain reliefs into
the holes in the access panel for the
electrical supply wires as necessary.
Three holes are provided. Each electrical
supply should be routed through its own
strain relief.
5. Route the electrical leads to the control
compartment. All electrical supplies that
will be connected to terminal blocks inside
the control compartment should be routed
from ABOVE the machine, if possible.
6. Refer to the electrical wiring diagram and
the electrical information labels next to the
terminal block(s). Connect the power
supply and ground leads to the terminal
block(s) inside the control compartment
as indicated.
Figure 3-8: Detergent connection
Load End
Insert
detergent
line through
conduit and
into wash
tank
7. If the machine is equipped with a fourth
electrical power supply terminal block,
access it as shown in Figure 3-7. A seal-
tight fitting is provided on the side of the
box that contains the terminal block.
For K-200 series machines equipped with
a fourth terminal block, route the supply
from BELOW the machine. For K-400
series machines equipped with a fourth
terminal block, route the supply from
ABOVE the machine.
8. Adjust all seal-tight fittings/strain reliefs to
fasten the wiring in place. You should
leave enough slack in the wiring to prevent
stress on the terminal connections.

3.8 Dispensing System Overview

K-Series rack conveyor dishwashers are
designed for use with a liquid rinse additive,
and either solid or liquid detergents. Detergent
and rinse additive injection is supplied by
external dispensing systems (supplied by
others).
Figure 3-9: Rinse aid connection
Unload End
Rinse
aid line
connects
here
S
3 - I
ECTION
NSTALLATION
Final rinse plenum chamber
1/4" NPT female
connection for rinse
pressure switch