Ethernet Cable Termination
It is essential that the Ethernet cables used be the correct type of cable and terminated with
the correct pinout. The cable can be terminated as either a patch cable or a crossover cable
and must be properly terminated relevant to the application (see
106 for termination details).
c
Reset button (recessed) — Press and hold in this recessed button to reset the
SMX to the default (factory setting) mode. The lit (green) LED blinks once.
d
Remote port — Connect a host device, such as a PC or touchpanel control, to the
SMX via this 9-pin D connector for serial RS-232 or RS-422 control.
Pin RS-232 Function
Pin
RS-232
1
—
1
—
2
Tx
2
TX
3
RX
3
Rx
4
—
4
—
5
Gnd
5
Gnd
6
—
6
—
7
—
7
—
8
—
8
—
9
—
9
—
Figure 3.
NOTES:
Input/Output Boards
The I/O boards on any unit may vary with each installation, depending on desired
configuration and use. All board types have the input and the output connectors clearly
marked, and each board has a 16-position rotary switcher (see m,
I/O plane address. An LED on the board indicates when power is present.
NOTE:
Figure 2
shows some, but not all, board variations that can be installed into an SMX frame.
Boards have different combinations of input and output connectors, depending on the
specific board installed. To install any board into an SMX frame slot (see
I/O Board Installation
e
SMX 44 DVI — Connect DVI single link high resolution digital input devices
(up to 1600 x 1200 @ 60 Hz) or HDTV devices up to 1080p, to any of the DVI-I female
input connectors. Connect suitable digital display devices to the DVI-I female output
connectors.
RS-422 Function
Function
RS-422
Not used
Not used
—
Transmit data
Transmit data
TX
Receive data
RX
Receive data
Not used
—
Not used
Signal ground
Gnd
Signal ground
Gnd
Not used
—
Not used
Not used
RX+
Not used
Rx+
Not used
TX+
Not used
Tx+
Not used
—
Not used
Remote Port Pin Assignments
•
See
SIS Configuration and Control
SMX Control Software
commands, and
control software.
•
The SMX can support either RS-232 or RS-422 serial communication protocol,
and can operate at 9600, 19200, 38400, or 115200 baud rates
(see
Operation
on page 13 to configure the RS-232/RS-422 port).
Boards with the same plane address switch simultaneously.
on page 10).
2
1
3
DVI-D INPUTS
SMX MD System MultiMatrix Switcher • Installation
Function
—
Not used
Not used
Tx
Transmit data (-)
Transmit data (-)
Receive data (-)
Rx
Receive data (-)
Not used
—
Not used
Signal ground
Signal ground
Not used
—
Not used
Receive data (+)
Receive data (+)
Transmit data (+)
Transmit data (+)
Not used
—
Not used
on page 34 for definitions of the SIS
on page 59 to install and use the
4
1
2
ADDRESS
DVI-D OUTPUTS
Ethernet Control
on page
5
1
9
6
Female
1
5
6
9
Male
figure
2) for setting the
SMX Frame and
3
4
8
Need help?
Do you have a question about the SMX System and is the answer not in the manual?