Diagnostic Guide; Diagnostic Tests - Whirlpool Cabrio WED6200S User Manual

Gas & electric dryers
Table of Contents

Advertisement

DIAGNOSTIC GUIDE

Before servicing, check the following:
Make sure there is power at the wall out-
let.
Has a household fuse blown or circuit
breaker tripped? Time delay fuse?
Is dryer vent properly installed and clear of
lint or obstructions?
All tests/checks should be made with a
VOM (volt-ohm-milliammeter) or DVM
(digital-voltmeter) having a sensitivity of
20,000 ohms per volt DC or greater.
Check all connections before replacing
components. Look for broken or loose
wires, failed terminals, or wires not pressed
into connectors far enough.
A potential cause of a control not function-
ing is corrosion on connections. Observe
connections and check for continuity with
an ohmmeter.
Connectors: Look at top of connector.
Check for broken or loose wires. Check
for wires not pressed into connector far
enough to engage metal barbs.
Resistance checks must be made with dry-
er unplugged or power disconnected.

DIAGNOSTIC TESTS

These tests allow factory or service person-
nel to test and verify all inputs to the machine
control electronics. You may want to do a
quick and overall checkup of the dryer with
these tests before going to specific trouble-
shooting tests.
ACTIVATING THE DIAGNOSTIC
TEST MODE
1.
Be sure the dryer is in standby mode
(plugged in with all indicators off, or with
only the Clothes Dry indicator on).
2.
Select any one button (except Pause/Can-
cel) and follow the steps below, using the
same button (remember the button):
Press/hold
Release for
Press/hold
2-5 seconds
2-5 seconds
2-5 seconds
Release for
Press/hold
2-5 seconds
2-5 seconds
6-18
3.
If this test mode has been entered suc-
cessfully, all indicators on the console
are illuminated for 5 seconds with 88
showing in the Estimated Time Remain-
ing two-digit display.
DIAGNOSTIC: Unsuccessful Entry
If entry into diagnostic mode is unsuccessful,
press the Pause/Cancel button twice, then
press the Power button.
If indicators come on, try to use a different
button than was used to activate the diag-
nostic test mode. If that button fails to enter
the diagnostic mode, something is faulty,
and it is not possible to enter the diagnostic
mode. Go to TEST #2.
If no indicators come on after pressing the
Power button, go to TEST #1.
DIAGNOSTIC: Saved Fault Codes
If there are saved fault codes, the most recent
fault code will alternately show "F-" and "XX"
where XX is the fault code.
Press and release
the same button
beep tone
used to activate
Diagnostics
Repeat
beep tone
Repeat
beep tone
Repeat
All indicators momentarily turn off, then stay on.
DIAGNOSTIC: Console Buttons
And Indicators
Pressing the console buttons or rotating the
cycle selector will sound a beep and will
turn on or off the corresponding indicators
as shown in Figure 2, Console Diagnostics.
Pressing Time Adjust (more time) will sound
a beep and turn the left digit of the display
on or off. Pressing Time Adjust (less time) will
sound a beep and turn the right digit of the
display on or off.
If indicators fail to turn on or off and beep
after pressing buttons or rotating the cycle
selector, go to TEST #6.
Second most recent fault code is displayed.
Third most recent fault code is displayed.
Fourth most recent fault code is displayed.