GAS SUPPLY CONNECTION
REQUIREMENTS
•
Use an elbow and a 3/8˝ flare x 3/8˝ NPT
adapter fitting between the flexible gas con-
nector and the dryer gas pipe, as needed
to avoid kinking.
•
Use only pipe-joint compound. Do not use
TEFLON
tape.
®†
•
This dryer must be connected to the gas
supply line with a listed flexible gas con-
nector that complies with the standard
for connectors for gas appliances, ANSI
Z21.24 or CSA 6.10.
®†
TEFLON is a registered trademark of E.I. DuPont
De Nemours and Company.
BURNER INPUT REQUIREMENTS
Elevations above 2,000 ft (610 m):
•
When installed above 2,000 ft (610 m) a
4% reduction of the burner B.T.U. rating
shown on the model/serial number plate is
required for each 1000 ft (305 m) increase
in elevation.
Gas Supply Pressure Testing
•
The dryer must be disconnected from the
gas supply piping system during pressure
testing at pressures greater than 1/2 psi.
DRYER GAS PIPE
•
The gas pipe that comes out through the
rear of your dryer has a 3/8˝ male pipe
thread.
A
2-16
2"
(5.1 cm)
³⁄
"
4
(1.9 cm)
³⁄
A.
" NPT dryer pipe
8