Type Test Specifications; Operating Environment - RuggedCom RuggedSwitch M2100 Installation Manual

Mil-std 19-port modular managed ethernet switch with gigabit uplink ports
Table of Contents

Advertisement

5.6 Type Test Specifications

Electrical Safety
Dielectric Withstand
High Voltage Impulse
Insulation Resistance
Electrical Environment
High Frequency Disturbance
(Oscillatory)
IEC Surge
IEC Fast Transient
ANSI/IEEE Fast Transient
IEC Radiated RFI Immunity
ANSI/IEEE Radiated RFI
Immunity
ESD
(Electrostatic Discharge)
Atmospheric Environment
Temperature (Dry Cold)
Temperature (Dry Heat)
Humidity

5.7 Operating Environment

Parameter
Ambient Operating
Temperature
Ambient Relative Humidity
Ambient Storage
Temperature
©
2008 RuggedCom Inc. All rights reserved
Levels
2 kV RMS for 1 minute
5 kV peak
500 VDC for 1 minute
Levels
2.5 kV @ 1MHz for 2s
4 kV / 2 kV
2 kV / 1 kV
4 kV
10 V/m
35 V/m
15 kV (air discharge)
8 kV (contact)
Levels
-40°C
85°C
95%
non-condensing
Test Db: 6 cycles, 55°C, 95% Humidity
Range
-40 to 85°C
5% to 95%
-40 to 85°C
28
Comments
ANSI/IEEE C37.90 (1989)
IEC 60255-5 (Section 6)
IEC 60255-5 (Section 8)
IEC 60255-5 (Section 6
Comments
ANSI/IEEE C37.90.1
IEC 60255-22-1
IEC 61000-4-5
(Level 4)
IEC 61000-4-4
(Level 4)
ANSI/IEEE C37.90.1
IEC 61000-4-3
ANSI/IEEE C37.90.2
IEC 61000-4-2
(Level 4)
Comments
IEC 60068-2-1
Test Ad: 16 hrs @ -40°C
IEC 60068-2-2
Test Bd: 16 hrs @ 85°C
IEC 60068-2-30
Comments
Ambient Temperature as
measured from a 30cm
radius surrounding the
center of the enclosure.
Non-condensing
Rev106