Type Test Specifications; Iec 61850-3 Type Tests; Rs900Gp Iec 61850-3 Type Tests - RuggedCom RuggedSwitch RS900GP Hardware Installation Manual

Table of Contents

Advertisement

3. Specifications

3.7. Type Test Specifications

3.7.1. IEC 61850-3 Type Tests

Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEC 60255-5
Table 3.9. RS900GP IEC 61850-3 Type Tests
RuggedCom® RuggedSwitch™
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips & Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on D.C. Power Supply
Dielectric Strength
H.V. Impulse
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
D.C. Power ports
Earth ground ports
Signal ports
D.C. Power ports
Signal ports
D.C Power ports
Earth ground ports
Enclosure ports
D.C. Power ports
Signal ports
differential mode @ 1MHz
D.C. Power ports
differential mode @ 1MHz
Signal ports
30V Continuous, 300V for 1s
D.C. Power ports
30V Continuous, 300V for 1s
D.C. Power ports
Signal ports
D.C. Power ports
Signal ports
5kV (Fail-Safe Relay output)
D.C. Power ports
21
RS900GP Installation Guide Rev 101
Test Levels
+/- 8kV
+/- 15kV
20 V/m
+/- 2kV @ 2.5kHz
+/- 2kV
+/- 2kV
+/- 2kV line-to-earth,
+/- 1.5kV line-to-line
+/- 1.5kV line-to-earth,
+/- 1kV line-to-line
10V
10V
10V
40 A/m continuous,
1000 A/m for 1 s
30% for 0.1s, 60% for
0.1s, 100% for 0.05s
2.5kV common, 1kV
2.5kV common, 1kV
10%
1.5kV AC (Fail-
Safe Relay output)
1.5kV DC
5kV
Severity
Levels
4
4
x
x
4
4
4
3
3
3
3
N/A
N/A
3
3
4
4
3
N/A
N/A
N/A
N/A