3.6 Type Test Specifications

Electrical Safety
Dielectric Withstand
High Voltage Impulse
Insulation Resistance
Electrical Environment
High Frequency Disturbance
(Oscillatory)
IEC Surge
IEC Fast Transient
ANSI/IEEE Fast Transient
IEC Radiated RFI Immunity
ANSI/IEEE Radiated RFI
Immunity
ESD
(Electrostatic Discharge)
Atmospheric Environment
Temperature (Dry Cold)
Temperature (Dry Heat)
Humidity
©
2008 RuggedCom Inc. All rights reserved
Levels
2 kV rms for 1 minute
5 kV peak
500 VDC for 1 minute
Levels
2.5 kV @ 1MHz for 2s
4 kV / 2 kV
2 kV / 1 kV
4 kV
10 V/m
35 V/m
15 kV (air discharge)
8 kV (contact)
Levels
-40°C
85°C
95%
Non-condensing
14
Comments
ANSI/IEEE C37.90 (1989)
IEC 60255-5 (Section 6)
IEC 60255-5 (Section 8)
IEC 60255-5 (Section 6
Comments
ANSI/IEEE C37.90.1
IEC 60255-22-1
IEC 61000-4-5
(Level 4)
IEC 61000-4-4
(Level 4)
ANSI/IEEE C37.90.1
IEC 61000-4-3
ANSI/IEEE C37.90.2
IEC 61000-4-2
(Level 4)
Comments
IEC 60068-2-1
Test Ad: 16 hrs @ -40°C
IEC 60068-2-2
Test Bd: 16 hrs @ 85°C
IEC 60068-2-30
Test Db: 6 cycles, 55°C, 95%
Humidity