Optional Instant Setback Cubby; Corrective Maintenance; Replacement Power Modules - Pace Sodr-Tek HEATWISE HW 50 Operation And Maintenance Manual

Hide thumbs Also See for Sodr-Tek HEATWISE HW 50:
Table of Contents

Advertisement

Using the Optional Instant Setback Cubby (Part Number 6019-0071-P1)
The HW 50 and TW 50 can be used with the optional Instant
Setback Cubby. When the TD-100 handpiece is inserted into
the Cubby, the system will automatically go into the Setback
Mode after 45 seconds of non-use. Once the Handpiece is
removed from the Cubby, it will return to normal operation.

Corrective Maintenance

Handpieces
Please refer to the TD-100/MT-100 Handpiece Manual for the maintenance procedures.
Power Source
Refer to the table below. Most malfunctions are simple and easy to correct.
Symptom
No power to
system
Handpiece will
not heat

Replacement Power Modules

©2005 PACE Inc., Annapolis Junction, Maryland
All Rights Reserved
Instant Setback Cubby Cable
Probable Cause
Solution
Blown Fuse
Replace the fuse (located in the AC Receptacle
Fuse Holder) with one of the same rated value.
No Supply Voltage
Verify that the AC outlet is active.
Defective Heater
Change Tip Cartridge. Refer to the TD-100/MT-
100 Handpiece manual for the maintenance
procedures.
Power Source
Contact PACE
Malfunction
Power Source Corrective Maintenance
Description
Power Modules
5/Green
5.5/Blue
6/Orange
6.5/Gold
7/Red
7.5/Purple
8/Black
8.5/Silver
PACE Part Number
1207-0362-01-P1
1207-0362-02-P1
1207-0362-03-P-1
1207-0362-04-P1
1207-0362-05-P1
1207-0362-06-P1
1207-0362-07-P1
1207-0362-08-P1
Page 14 of 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sodr-tek tempwise tw 508007-04258007-04268007-04568007-04578007-0458 ... Show all

Table of Contents