Exiting Set-Up Mode

9. The LED Display now reads "End". The Set-Up Mode procedure is now complete.
Choose one of the following steps:
Press and release the Scroll Up Key ( ) to save the changes, exit the Set-Up
Menu and return to normal operation.
Press and release the Scroll Down Key ( ) to return to the start of the Set-Up
Menu without saving any changes. Go back to step 3, Password Entry.

Corrective Maintenance

Display Message Codes

Display
Message
The incorrect password has been entered. The displayed message will time out after
"no"
6 seconds and revert to normal operation. Enter the correct password.
"Over Current Error" The Heater circuit is shorted or the handpiece has failed. Inspect
"OCE"
handpiece and heater element, replace as needed.
"Open Sensor Error" Unit is unable to sense the sensor from the handpiece. Make
"OSE"
sure handpiece is connected. Inspect handpiece and heater element for damage or
wear, replace as needed.
The AutoOff feature has activated, turning off the handpieces. Press any button on
"OFF"
the unit to return to normal operation.
Power Source Issues
Most malfunctions are simple and easy to correct.
Symptom
No power to system
Handpiece will not heat
Little to no vacuum or air
flow, heater works and
pump is running

Spare Parts

Description
Fuse 1 Amp, Time Lag (for 115V)
Fuse 0.50 Amp, Time Lag (for 230V)
Optional under shelf mounting bracket
Pressure Knob assembly

Service

Please contact PACE or your local distributor for service and repair.
©2022 PACE Inc., Vass, North Carolina, All Rights Reserved
https://paceworldwide.com/
Description
Probable Causes
Blown Fuse
Defective Heater Element
Power Source Malfunction
Kinked air hose
Worn pump
Full SodrTrap or VisiFilter
Solution
Replace the fuse (located in the AC
Receptacle Fuse Holder) with one of
the same rated value.
Refer to the appropriate handpiece
manual
Contact PACE
Inspect hoses and filters, move or
replace as needed.
Replace vacuum pump
Empty solder collection trap and
inspect VisiFilter element.