Kyocera KM-1820 Service Manual page 255

Includes: fax system (k)
Hide thumbs Also See for KM-1820:
Table of Contents

Advertisement

Error code
U03500
In confidential polling reception, the specified confidential box No. was not registered in the
destination. Or, in interoffice subaddress-based bulletin board reception, the specified
Subaddress confidential box number was not registered in the destination unit. Or, the
destination was being accessed.
U03600
Confidential polling reception was interrupted because of a mismatch in specified confidential
box No. Or, an interoffice subaddress-based bulletin board reception was interrupted because of
a mismatch in the specified subaddress confidential box number.
U03700
Confidential polling reception failed because the destination unit had no confidential polling
transmission capability or data was not accumulated in any box in the destination unit. Or, data
was not stored in any subaddress confidential box in the destination unit.
U04000
The confidential box specified for confidential transmission was not registered in the destination
unit. Or, in interoffice subaddress-based transmission mode, the specified subaddress box
number was not registered in the destination unit. Or, the destination was being accessed.
U04100
Confidential transmission failed because the destination unit had no confidential capability. Or,
subaddress-based transmission failed because the destination unit had no subaddress-based
reception capability.
U04200
In encrypted transmission, the specified encryption box was not registered in the destination unit.
U04300
Encrypted transmission failed because the destination unit had no encrypted communication
capability.
U044XX
Communication was interrupted because of an encryption key error during encrypted
transmission (refer to page 1-4-10 "U044XX error code table").
U04500
Encrypted reception was interrupted because of a mismatch in encryption keys.
U05000
In transmission with a specified number, the set number of originals was different from the
number of transmitted originals.
U05100
Password check transmission was interrupted because the permit ID did not agree.
U05200
Password check reception was interrupted because the permit ID did not agree.
U05300
Destination unit in password check reception mode did not receive data because the permit ID
did not agree.
U06199
When the original size setting was Letter/A4, it was going to transmit the original of Legal/Folio
size from document processor, and reading was stopped because the setting and original was
not match.
U09000
G3 communication was attempted but failed because the destination unit was a G2 machine.
U12000
Relay broadcast was requested from a command station but memory overflowed during
reception.
U12100
Relay was commanded but memory overflowed in the destination unit (relay station).
U14000
Memory overflowed during confidential reception. Or, in subaddress-based confidential
reception, memory overflowed.
U14100
Memory overflowed in the destination unit during confidential transmission. Or, in interoffice
subaddress-based transmission, memory overflowed in the destination unit.
U19000
Memory overflowed during memory reception.
U19100
Memory overflowed in the destination unit during transmission.
U19200
Memory transmission failed because a decoding error occurred.
U19300
Transmission failed because an error occurred during JBIG encoding.
U19400
Reception failed because an error occurred during JBIG decoding.
Description
3JG
1-4-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1118mfp

Table of Contents