Mw Gw Link Error; Comms Timeout 5 Seconds; Eeprom Read Error; Lid Lock Open Circuit - Fisher & Paykel SmartDrive Service Manual

Smartdrive washing machine
Hide thumbs Also See for SmartDrive:
Table of Contents

Advertisement

231. (11100111) Phase 6 - MW GW Link Error
Component has failed on the display board.
Primary Fault:
Action:
232. (11101000) Phase 6 - COMMS Timeout 5 Seconds
IW only problem, either the Display or Motor Control Module has not
responded in time.
Primary Fault:
Action:
Secondary Fault:
Action:
233. (11101001) Phase 6 - EEPROM Read Error
Problem reading the EEPROM data coming from the Motor Control
Module.
Primary Fault:
Action:
234. (11101010) Phase 6 - Lid Lock Open Circuit
Check Harness to Lid Lock and connections at the Motor Control
Module and lid lock ends.
Primary Fault:
Action:
Secondary Source: Lid Lock has failed to be activated.
Action:
Tertiary Source:
Action:
Display Module fault.
Replace Display Module.
Display Module.
Replace Display Module.
Motor Control Module.
Replace Motor Control Module.
Motor Control Module faulty.
Replace Motor Control Module.
Connector to the harness. Either end could be
at fault.
Replace Harness.
Replace Lid Lock housing.
Motor Control Module has not responded to the
Lid Lock being activated.
Check the lid has a Tang and is fitted correctly
to activate the Lid Lock. If this is all in order, the
Motor Control Module must be at fault and
needs to be replaced.