Display / Motor Control Module Out Of Sequence; Pump Circuit Error; Water Valve Fault; Brake Resistor Fault - Fisher & Paykel SmartDrive Service Manual

Smartdrive washing machine
Hide thumbs Also See for SmartDrive:
Table of Contents

Advertisement

Liquid Crystal Display.
Primary Source:
Action:
28 – 30. (000111xx)Phase 1 - Display / Motor Control
Refer to fault code 17
32. (00100000) Phase 1 - Pump Circuit Error
The Display Module has detected that the pump is on when it is off.
Primary Source:
Action:
33. (00100001) Phase 1 - Water Valve Fault
The Module has detected a water valve fault.
Primary Source:
Action:
Secondary Source: Water valve coil faulty.
Action:
34. (00100010) Phase 1 - Brake Resistor Fault
The circuit that controls the braking of the motor is faulty.
Primary Source:
Action:
Secondary Source: Display Module.
Action:
IW Display Module.
Replace IW Display Module.
Module Out of Sequence
Display Module.
1. Check for moisture in the console area.
2. Replace the Display Module.
Water valve connection.
Check that both valves are connected up
properly.
1. Check the valve coils are not open circuit.
2. Replace Display Module if the valve coils are
not faulty.
Motor Control Module.
Replace Motor Control Module.
Replace the Display Module.
If the Display Module corrects the fault, then refit
the original Motor Control Module.