IW SmartDrives, Phase 5 and 6:
10. (00001010) Phase 1 to 6 - Temperature Sensor
The temperature sensor may be open circuit or the ambient
temperature is below minus 10 o C. This fault is only applicable in the
Intuitive Washer and the GW models.
Primary Source:
Action:
11. (00001011) Phase 1 to 6 - Pressure Sensor Fault
While measuring the water level, the Motor Control Module micro has
detected a negative pressure. Reconnecting the pressure tube to the
pressure sensor while the bowl has been partly filled with water may
have caused this.
Primary Source:
Action:
button until the hold LED is on for 7kg
SmartDrives.
To access Size Setting Mode, push and hold the
FABRIC CARE button and then press the
POWER button. Select the correct size on the
display by pushing the White button next to the
correct size (Phase 5) or using the ADJUST
button to highlight the right size (Phase 6). Size
setting is then set by pressing the POWER
button. Powering off will set the size into the
memory. Check the size is set before starting a
cycle.
(Thermistor) Error
Thermistor.
Replace Thermistor.
Pressure Tube.
1. Check bowl is fully pumped out. Remove
pressure tube from pressure sensor, clear
pressure tube of any water and reconnect
tube.
2. If fault is still present, replace the Motor
Control Module. (Display Module Phase 1.)