58. (00111010) Phase 4 to 5 - Pressure Transducer at
When the pause or delay start is pressed to start the SmartDrive, the
Display Module has checked the memory and found the count greater
than expected.
Primary Source:
Action:
59. (00111011) Phase 4 to 5 - I D Out of Range Fault
When the pause or delay start is pressed to start the SmartDrive, the
Display checked the physical ID and found it was out of range.
Primary Source:
Action:
60. (00111100) Phase 4 to 6 - Motor Control Module
On power up, the Motor Control Module has checked its memory
against a known reference and found differences.
Primary Source:
Action:
61. (00111101) Phase 4 - Brown Out During Motor
The Motor Control Module has been attempting to perform an internal
EEPROM write. Prior to writing, the Motor Control Module has tested
the 15 volt supply and found that it is below the safety level for writing
EEPROM and has reported this to the display.
Primary Source:
Action:
62. (00111110) Phase 5 - Pump Over Current
The Motor Control Module has detected an excessive pump current.
Primary Source:
Action:
Secondary Source: Motor Control Module.
Action:
Maximum Adjustment Fault
Motor Control Module.
Replace Motor Control Module.
Display Module.
Replace Display Module.
Memory Check Fault
Motor Control Module.
Replace Motor Control Module.
Control Module EEPROM Write Fault
Motor Control Module.
Replace Motor Control Module.
Pump.
Replace Pump.
Replace Motor Control Module.
39