63. (00111111) Phase 5 - Pump Comms Error
The Motor Control Module has detected an internal communications
problem between its main control system and the pump control
system.
Primary Source:
Action:
64. (01000000) Phase 5 and 6 - Pressure Transducer
The Motor Control Module has received signals from the water level
sensor (Ptx) below normal frequency values.
Primary Source:
Action:
65. (01000001) Phase 5 and 6 - Pressure Transducer
The Motor Control Module has received signals from the water level
sensor (Ptx) above normal frequency values.
Primary Source:
Action:
66. (01000010) Phase 6 - Pressure Transducer (Ptx)
Note: this supersedes Fault code 65 from V41 Motor Control Module
code onwards.
The Motor Control Module has received signals from the water level
sensor (Ptx) above normal frequency values.
Primary Source:
Action:
81. - 95. (0101xxxx) Phase 2 to 3 - Display/ Motor Control
104. (01101000) Phase 2 to 6 - See Fault Code 106
Motor Control Module.
Replace Motor Control Module.
(Ptx) Error - Frequency < 66 kHz
Motor Control Module.
Replace Motor Control Module.
(Ptx) Error - Frequency > 90 kHz
Motor Control Module.
Replace Motor Control Module.
Error - Frequency > 90 kHz
Motor Control Module.
Replace Motor Control Module.
Module. See Fault Code 106
40