163. (10100011) Phase 4 to 6 - Valve Reset Pin Connect
The Motor Control Module has sensed the PCB connection is open
circuit. The cold valve cannot operate with this condition.
Primary Source:
Action:
164. (10100100) Phase 4 to 5 - Brake Function Time-out
This fault indicates that the Motor Control Module has been attempting
to brake for 20 seconds. As all spin loads should come to rest within
10 seconds, something has gone wrong during the brake to prevent
the bowl stopping in time.
Primary Fault:
Action:
Secondary Source: Motor Control Module (Phase 4), RPS (Phase
Action:
192. (11000000) Phase 4 to 5 - Motor PMW Reset Pin
The Motor Control Module has sensed an open circuit between pins
30 and 31. The motor cannot operate with this condition.
Primary Source:
Action:
230. (11100110) Phase 6 - EEPROM Value Out of Range
Wrong version detected.
Primary Fault:
Action:
Fault
Motor Control Module.
Replace Motor Control Module.
Fault
Wiring.
Measure / check the motor harness, connectors
and motor for continuity. This can be done by
taking a resistance measurement between
phases of the motor harness at the Motor
Control Module end. Nominal resistance should
be approximately 2.6 ohms for Phase 1, 12.2
ohms for Phases 2, 3 and 4, and 32 ohms for
Phases 5 and 6.
5).
Replace Motor Control Module (Phase 4), or
Rotor Position Sensor (Phase 5).
Connect Fault
Motor Control Module.
Replace Motor Control Module.
Motor Control Module is the wrong version.
Change Motor Control Module.