8.7

Removal of Motor Control Module

(a) Follow the procedure for removal of
Console. (Refer to Section8.2).
(b) Disconnect the Display wiring harness from
the Motor Control module & place console
out of the way.
(c) Disconnect all remaining wiring harnesses
to the Motor Control Module.
(d) Remove the pressure tube by squeezing on
the legs of the spring clip. Pull gently on
the tube to slide it off the spigot. Note: If
too much force is used on removal or
reinsertion, damage to the pressure
transducer may occur.
(e) Remove the screw holding the Motor
Controller from the front edge. Pull the tab
on the top deck harness clamp towards the
front to release the Motor Control Module.
(f) Lift the Motor Control Module upwards at
the front and out.
Reassembly:
Refit in reverse manner. Important: When refitting the pressure tube to pressure transducer
ensure that the pressure tube is clear of any water droplets before operating the machine on a fill
cycle. If the basket is full of water, drain the water then blow down the tube.
8.8

Removal of Cord Set

(a) Follow the procedure for removal of water
valves. (Refer to Section 8.4).
(b) Disconnect the mains plug to the Motor
Control Module.
(c) Slide the strain relief to the left and slide
out.
Reassembly:
Refit in reverse manner.