Honeywell 9782 Series Operator's Manual page 81

Two cell conductivity/resistivity analyzer/controller
Table of Contents

Advertisement

PARAMETER
configuration: retransmission 0%
configuration: retransmission 100%
configuration: CAT control setpoint value
configuration: alarm setpoint value
configuration: configuration: On/Off control cycle timer
setpoint value
configuration: PFT control setpoint value
configuration: DAT control setpoint value
configuration: CAT control proportional band limit
configuration: alarm deadband
configuration: On/Off control cycle timer deadband
configuration: PFT control proportional band limit
configuration: DAT control proportional band limit
configuration: alarm delay
configuration: process variable or computed value to
be used as basis for discrete control output
configuration: process variable or computed value
alarmed
configuration: alarm action
configuration: On/Off control cycle timer period
configuration: On/Off control cycle timer "on" time
configuration: PFT control maximum pulse frequency
configuration: DAT control cycle period
configuration: 24-hour clock set mode
configuration: 24-hour clock set hour
configuration: 24-hour clock set minute
configuration: AutoClean timer set day
configuration: AutoClean timer set hour
configuration: AutoClean timer set minutes
7/99
9782 Series Conductivity/Resistivity Analyzer/Controller - Operator's Manual
I/O Setup and System Configuration
CHOICES or RANGE
(Default is underlined)
range depends on measurement type and cell constant;
default is value of lower range limit
range depends on measurement type and cell constant;
default is value of upper range limit
range depends on measurement type and cell constant;
default is value of upper range limit
0 to 100 seconds, default = 0
C1 [Cell 1 value]
C2 [Cell 2 value]
TMP1 [temperature value from Cell 1]
TMP2 [temperature value from Cell 2]
T1/2 [temperature 1 and/or 2 - only available for
alarming]
Cell
Cell
RATO [computed ratio:
%REJ [computed percent rejection:
%PSG [computed percent passage:
DIFF [computed difference:
CO2 [computed parts per million carbon dioxide -
9782C-S0 only]
HIGH
LOW
0 to 1000 seconds, default = 60
0 to 100% at 1% resolution, default = 100
1 to 200 pulses per minute, default = 60
0 to 200 seconds, default = 60
OFF
ON W/ RESET
ON W/O RESET
0 to 24, default = 1
0 to 59, default = 0
0 to 28, default = 0
0 to 24, default = 1
0 to 59, default = 0
1
2
]
Cell
1
(
1
)x
100
Cell
2
]
Cell
1
x
100
Cell
2
]
Cell
1
Cell
2
]
5-25