At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
SET MAX SET PASSWORD data content
Word
0
1 - 16
17 - 255
(36-3)
SET MAX LOCK (F9)
After this command is completed any other Set Max commands except SET MAX UNLOCK and
SET MAX FREEZE LOCK are rejected. The device remains in this state until a power cycle or
the acceptance of A SET MAX UNLOCK or SET MAX FREEZE LOCK command.
At command issuance (I/O registers setting contents)
1F7
(CM)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I/O registers contents to be read)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
Status information
1
L
1
DV
xx
xx
xx
xx
Error information
Reserved
Password (32 bytes)
Reserved
1
1
1
1
1
L
1
DV
xx
xx
xx
xx
0
0
0
0
Status information
1
L
1
DV
xx
xx
xx
xx
Error information
C141-E110-02EN
xx
Content
1
0
0
1
xx
0
0
1
0
xx
5 - 71