SIP User's Manual
Parameter
MAX Incoming ANI Digits
[CasStateMachineMaxNumOfIncomingANI
Digits]
Collet ANI
[CasStateMachineCollectANI]
Digit Signaling System
[CasStateMachineDigitSignalingSystem]
3.3.3.2

Configuring the Trunk Settings

The 'Trunk Settings' page allows you to configure the device's trunks. This includes
selecting the PSTN protocol and configuring related parameters.
Some parameters can be configured when the trunk is in service, while others require you
to take the trunk out of service (by clicking the Stop
trunk, all calls are dropped and no new calls can be made on that trunk.
You can also deactivate a trunk (by clicking the
Deactivation temporarily disconnects (logically) the trunk from the PSTN network. Upon
trunk deactivation, the device generates an AIS alarm on that trunk to the far-end (as a
result, an RAI alarm signal may be received by the device). A subsequent trunk activation
(by clicking the Activate
AIS alarm. Trunk deactivation is typically used for maintenance such as checking the
trunk's physical integrity.
For a description of the trunk parameters, refer to ''
Notes:
Version 6.0
button), reconnects the trunk to the PSTN network and clears the
During trunk deactivation, trunk configuration cannot be performed.
A stopped trunk cannot also be activated.
Description
Defines the limitation for the maximum ANI digits
that need to be collected. After reaching this number
of digits, the collection of ANI digits is stopped.
The value must be an integer. The default value is -1
(use value from CAS state machine).
In some cases, when the state machine handles the
ANI collection (not related to MFCR2), you can
control the state machine to collect ANI or discard
ANI.
[0]
No = Don't collect ANI.
[1]
Yes = Collect ANI.
[-1]
Default = Default value - use value from CAS
state machine.
Defines which Signaling System to use in both
directions (detection\generation).
[0]
DTMF = Uses DTMF signaling.
[1]
MF = Uses MF signaling (default).
[-1] Default = Default value - use value from CAS
state machine.
button). Once you have "stopped" a
Deactivate button) for maintenance.
PSTN Parameters''