9.5
Removal of Fan Motor
Procedure
Step
1. Remove the back cover.
1
Remove the 2 screws
from the front top and
the 3 screws from the
back cover.
2
Untie the power cord.
Photocatalytic Air Purifier L-Series
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Preparation
Remove the display cover
ASSY according to
"Removal of Control /
Display PCB".
(R12362)
Back cover
(R12363)
Power cord
(R12364)
Removal Procedure
Points