Quick Reference Table of Maintenance

Quick Reference Table of Maintenance
WARNING
Before performing maintenance, stop the unit and disconnect the power plug. (It may cause electric shock or injury.)
Remove the parts for maintenance in numerical order.
For details on removing and attaching each part, see
1
Front panel
If it gets dirty
Wipe
• Wipe off the dirt with a cloth
slightly moistened with water.
• In the case of heavy dirt, wipe it
off with a cloth moistened with
neutral detergent.
• Do not use hard brushes, etc.
WARNING
• Do not use gasoline, benzene, thinner, scouring powder,
kerosene, alcohol, etc.
(Cracking, electric shock or fire may occur.)
• Do not wash the main unit with water.
(Electric shock, fire or malfunction may occur.)
15
22
Ionising frame
2
3
Prefilter
Once every 2 weeks
Vacuum cleaner
Rinse with water
• Use a vacuum cleaner to
• Use a vacuum cleaner to remove the dust.
• Soak in lukewarm water or water. (About 1 hour)
remove the dust from the
prefilter, and wash it with water.
• Dry throughly after soaking.
• In the case of heavy dirt, wash
the prefilter with a soft brush or
neutral detergent and dry it well
in the shade.
Dry the prefilter completely before
using it because the "UNIT1" lamp
may light up if any water drops
remain on the prefilter.
.
Page 17.
Opposing pole plates
Ionised wire
UNIT1
4
(Plasma ioniser)
The figure above shows
UNIT1 after the opposing
pole plates are removed.
If the "UNIT1"
Once every 3 months or if
lamp lights
the "UNIT2" lamp lights
Soak, drain and dry
Wipe
Care and Cleaning
Page 19, 20.
NOTE
• When detergent is used, wipe the detergent off the surface to
prevent any residue.
• Do not dry the prefilter in a place exposed to direct sunlight.
• Do not use hot water with a temperature of 50˚C or higher for
cleaning the parts.
• Do not dry the parts over a fire.
It may cause discolouration or deformation of the parts and the
parts may become unusable.
Photocatalytic Air Purifier L-Series
SiBE811120
UNIT2
(Streamer unit)
Soak, drain and dry
Wipe