SiBE811120
9.4
Removal of Control / Display PCB
Procedure
Step
Remove the 3 screws
1
of the display cover
ASSY.
Pull the display cover
2
ASSY.
3
Disconnect the relay
connector [S128] from
the control / display
PCB.
Photocatalytic Air Purifier L-Series
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Display cover ASSY
(R12355)
(R12356)
[S128]
Control/display PCB
(R12357)
Removal Procedure
Points
When reassembling,
connect the relay connector
securely until the blue part is
not to be seen.
47