Step
3. Remove the pre-filter.
Pull the recessed part
1
of the pre-filter upper
section and unfasten
the right and left hooks
(4 in total).
Remove the pre-filter.
2
4. Remove the plasma
ionizer unit.
Hold the handles of the
1
plasma ionizer unit. Pull
the plasma ionizer unit
to unfasten the hooks
and lift it up to remove.
Photocatalytic Air Purifier L-Series
Procedure
Hook
Pre-filter
Handle
Plasma ionizer unit
When reassembling, fit the
pre-filter as the "FRONT"
mark comes front.
Recessed part
with "FRONT"
mark
Hook
(R12334)
When reassembling, fit the 4
hooks of the pre-filter into the
4 holes of the plasma ionizer
unit.
The upper left hook is
shaped differently from the
others.
To prevent the air purifier
from falling down, support
the air purifier while
removing the plasma ionizer
unit.
Hook
(R12336)
Removal Procedure
Points
(R12335)