Daikin MC707VM-S Operation Manual

Daikin MC707VM-S Operation Manual

Photocatalytic air purifier
Hide thumbs Also See for MC707VM-S:

Advertisement

OPERATION MANUAL
MODEL
MC707VM-S
MC707VM-W
PHOTOCATALYTIC AIR PURIFIER
RIF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC707VM-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin MC707VM-S

  • Page 1 OPERATION MANUAL MODEL MC707VM-S MC707VM-W PHOTOCATALYTIC AIR PURIFIER...
  • Page 2: Table Of Contents

    Model MC707VM-S, MC707VM-W (It is safe because high-speed electron is generated and nerated and erated and Required power supply 1ø220-240/220-230V 50/60Hz disappeared within the system.)
  • Page 3: Safety Precautions

    Safety Precautions Keep this manual where the operator can easily find them. Heat can discolor and deform the casing. Read this manual attentively before starting up the unit. For the reason of safety the operator must read the following Keep the unit and remote control minimum 2m from cautions carefully.
  • Page 4: Names And Operation Of Each Part

    Names and Operation of each Part Main unit Front Shock-absorbing material (cardboard) Be sure to remove the shock-absorbing material before operating. (page 5.) Pleated filter Rear Rear 1 Front panel 14 Air inlet 2 Main unit display 15 Remote controller storage slot (page 4.) Shows operation status.
  • Page 5: Main Unit Display

    Main unit display Air is taken in from here and the dust sensor detects the dirty state Lit during automatic operation. ration. of the air. (page 7.) (page Lit by the set airflow rate setting. ow rate setting. te setting. Detects the dirty state of the air and indicates the results.
  • Page 6: Preparation Before Operation

    Preparation Before Operation Remote controller setup Remote controller Do not drop or place the remote controller in water. (Damage may occur.) preparations Do not press the remote controller buttons with sharp objects. (Damage may occur.) controller but the remote controller The signals may not be received well of electronic lighting style cannot be used as is without first fluorescent lamps (such as inverter fluorescent lamps) are in the...
  • Page 7 Pleated filter The side with the three holes goes up. pre-filter. Pull out in front to remove. Pre-filter The white side should be facing you. Deodorizing (2 locations) of the plasma ionizer. ionizer. zer. catalyst unit Securing tape Top hooks (2 locations) Top hooks (2 Holes (2 locations)
  • Page 8: How To Operate

    Preparation Before 5 When you want to remove pollen Operation “ ” M (Standard) and “ ” L (Low) will catch pollen before they fall on the floor. Installation of main unit To install the unit, comply with the following standards to ensure performance. 〈...
  • Page 9: Care And Cleaning

    Care and Cleaning Cleaning chart sensor the air inlet for the dust/ CAUTION odor sensor. Stop operation and pull the power plug before cleaning. cleaner for cleaning. Air inlet for the dust sensor Air inlet for the odor sensor Cleaning the front panel cloth or tissue slightly soaked with water.
  • Page 10 Care and Cleaning Cleaning the pre-filter NOTE It is recommended to clean the pre-filter every two weeks. Securely close the panel. Failing to do so may cause activation of the safety switch and out of unit operation. dent at bottom of the CAUTION Front main unit, hold bottom...
  • Page 11 Replace a pleated filter 5) Insert the pleated filter into the left and right hooks. 6) Secure the pleated filter with the tape. turn on (page 9.) 2 hooks. (page 6.) Press the reset switch with a sharp material such as a tooth pick to k to Hooks turn off the replacement...
  • Page 12 Care and Cleaning Clean the plasma ionizer the plasma ionizer. Top hooks (2 locations) Blink CAUTION Stop operation before cleaning and be careful not to cut your hands Bio-antibody filter with the opposing pole plate or ionizer wires. (It is safer to use rubber gloves.) 2 hooks.
  • Page 13 Contents 1) Ionizing frame 2) Ionized wire 3) Streamer discharger 4) Opposing pole plate Remove each part. (page 11.) (page 11.) (page 11.) Vacuum dusts on the surface with a cleaner. Vacuum Caution Soak in water or warm water with liquid mild detergent.
  • Page 14 Care and Cleaning 3) Ionizing frame CAUTION When cleaning the unit, be careful not to cut your hands with the your finger does not reach. opposing pole plate or ionizer wires. (It is safer to use rubber gloves.) When cleaning the unit, be careful not to cut the ionizer wires. Be sure to do in a shower-proof place such as bathroom or sink in a kitchen.
  • Page 15 1) Securely insert the opposing pole plate into the hooks (2 locations 1) Insert bottom of the streamer discharger to the ionizer frame. in the middle) of the plasma ionizer. Insert downward 2) Attach the opposing pole plate while opening the knobs (one at a 2) Insert top of the streamer discharger.
  • Page 16: Optional Accessories

    Care and Cleaning Cleaning the deodorization catalytic unit NOTE Vacuum dusts with a If the operation of 4. is not performed, the unit will not return to cleaner without normal operation mode. If the operation of 4. is performed, during removing from the the settings, the settings will not be correct.
  • Page 17: Frequently Asked Questions

    Question Answer This is due to dusts built up in the dust sensor. Vacuum dusts from the air inlet with a crevice nozzle of a cleaner and then manually operate the unit for a while. The sensor will go back to normal. This is because react time of the dust sensor differs depending on the size of room.
  • Page 18 2SB63475-11E...
  • Page 19 AirControl Systems AirControl Systems Andil House Andil House Court Street Court Street Trowbridge BA14 8BR Trowbridge BA14 8BR Tel: 0044 (0)1225 752494 Tel: 0044 (0)1225 752494 www.air-purifiers.org.uk www.air-purifiers.org.uk 3P167171-1A M05B061A (0511) HT...

This manual is also suitable for:

Mc707vm-w

Table of Contents

Save PDF