Removing and attaching the opposing pole plates
CAUTION
Wear rubber gloves to remove and attach the opposing pole plates. Hands can be cut on the opposing pole plates and ionised wires.
Front panel
Remove
1
Remove the front panel and UNIT1.
2
Remove the opposing pole plates from
the rear of UNIT1.
• Pinching together the white and green knobs (2 sets on
the right and left), lift the opposing pole plate up and
remove it.
Wear rubber
gloves.
Ionised wire
Be careful not to cut the
internal ionised wires.
Photocatalytic Air Purifier L-Series
UNIT1
Opposing pole plates
Ionised wire
Ionising frame
Page 17.
Pinching the sets of knobs
on the right and left at the
Opposing
same time makes it easier
pole plates
to remove the opposing
pole plate.
Knob
Knob
(green)
(white)
Ionising frame
Attach
1
Attach the opposing pole plates.
1) Fit the opposing pole plate over the knobs (2 sets on the
right and left) on the ionising frame.
The opposing pole plates have no difference between the
upper and the lower, or between the right and the left.
Attach them so that the arrow is visible.
Wear rubber
gloves.
Opposing
pole plates
Ionising frame
2) Insert securely until it clicks.
3) Attach the other opposing pole plate.
2
Attach UNIT1 and the front panel.
Operation Manual
Arrow
Knob