Specifications
Slim Ceiling Mounted Duct Type
Model
1 Cooling Capacity
2 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows×Stages×FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Air Flow Rate (H/L)
External Static Pressure
4
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Piping
Gas Pipes
Connections
Drain Pipe
Machine Weight (Mass)
5 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
26
FXDQ07MVJU
Btu/h
7,500
Btu/h
8,500
Galvanized Steel Plate
in
7-7/8 × 27-9/16 × 24-7/16
2 × 12× 17
ft²
1.36
Sirocco Fan
HP
0.08
cfm
280/226 (H/L)
Pa
30-10
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Foamed Polyethylene
Removal, Washable, Mildew Proof
φ
in
1/4 (Flare Connection)
φ
in
1/2 (Flare Connection)
VP20
in
(External Dia. 1-1/32 Internal Dia. 25/32)
Lbs
dBA
33/29
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers, Conduit Mounting Plate,
Insulation Tube.
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB, 67°FWB
|Outdoor temperature: 95°FDB
Equivalent ref. piping length: 25ft (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping length: 25ft (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure means
" High static pressure – Standard ".
5 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of installation conditions.
FXDQ09MVJU
Galvanized Steel Plate
7-7/8 × 27-9/16 × 24-7/16
Microprocessor Thermostat
for Cooling and Heating
Foamed Polyethylene
Removal, Washable, Mildew Proof
φ
1/4 (Flare Connection)
φ
1/2 (Flare Connection)
(External Dia. 1-1/32 Internal Dia. 25/32)
51
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers, Conduit Mounting Plate,
Insulation Tube.
C:3D051780A
9,500
10,500
2 × 12× 17
1.36
Sirocco Fan
0.08
280/226 (H/L)
30-10
Direct Drive
Microprocessor Thermostat
Removal, Washable, Mildew Proof
VP20
(External Dia. 1-1/32 Internal Dia. 25/32)
51
33/29
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers, Conduit Mounting Plate,
Insulation Tube.
SiUS30-604
FXDQ12MVJU
12,000
13,500
Galvanized Steel Plate
7-7/8 × 27-9/16 × 24-7/16
3 × 12× 17
1.36
Sirocco Fan
0.08
280/226 (H/L)
30-10
Direct Drive
for Cooling and Heating
Foamed Polyethylene
φ
1/4 (Flare Connection)
φ
1/2 (Flare Connection)
VP20
51
33/29
R-410A Series
Specifications