Specifications
Ceiling Mounted Built-In Type
Model
1 Cooling Capacity
2 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows×Stages×FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Air Flow Rate (H/L)
External Static Pressure
4
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Piping
Gas Pipes
Connections
Drain Pipe
Machine Weight (Mass)
5 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Model
Decoration
Panel Color
Panel
Dimensions: (H×W×D)
(Option)
Weight
Standard Accessories
Drawing No.
Notes:
28
FXSQ12MVJU
Btu/h
12,000
Btu/h
13,500
Galvanized Steel Plate
in
11-7/8 × 21-5/8 × 31-1/2
3 × 14 × 14
ft²
0.95
D18H3A
Sirocco Fan
HP
0.07
cfm
340/230
in. Aq
0.37-0.19-0.06
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Glass Fiber
Resin Net (with Mold Resistant)
φ
in
1/4 (Flare Connection)
φ
in
1/2 (Flare Connection)
VP25
in
(External Dia. 1-1/4 Internal Dia. 1)
Lbs
dBA
41/35
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
BYBS32DJW1
White (10Y9/0.5)
in
2-1/8 × 25-5/8 × 19-5/8
Lbs
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB, 67°FWB
Outdoor temperature: 95°FDB
Equivalent ref. piping length: 25ft (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping length: 25ft (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure means
" High static pressure – Standard – Low static pressure ".
5 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of installation conditions.
FXSQ18MVJU
Galvanized Steel Plate
11-7/8 × 27-1/2 × 31-1/2
0.38-0.19-0.06
Microprocessor Thermostat
for Cooling and Heating
Resin Net (with Mold Resistant)
φ
1/4 (Flare Connection)
φ
1/2 (Flare Connection)
(External Dia. 1-1/4 Internal Dia. 1)
69
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
R-410A Series
BYBS45DJW1
White (10Y9/0.5)
2-1/8 × 31-1/2 × 19-5/8
6.6
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
18,000
20,000
3 × 14 × 14
1.42
D18H2A
Sirocco Fan
0.11
530/390
Direct Drive
Microprocessor Thermostat
Glass Fiber
Resin Net (with Mold Resistant)
VP25
(External Dia. 1-1/4 Internal Dia. 1)
73
44/38
Fuse, Thermal Protector for Fan Motor
Electronic Expansion Valve
7.7
Operation Manual, Installation Manual,
Paper Pattern for Installation, Drain
Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws,
Washers.
C:3D042684
SiUS30-604
FXSQ24MVJU
24,000
27,000
Galvanized Steel Plate
11-7/8 × 39-3/8 × 31-1/2
3 × 14 × 14
2.38
2D18H2A
Sirocco Fan
0.17
740/490
0.51-0.29-0.06
Direct Drive
for Cooling and Heating
Glass Fiber
φ
3/8 (Flare Connection)
φ
5/8 (Flare Connection)
VP25
95
44/38
R-410A Series
BYBS71DJW1
White (10Y9/0.5)
2-1/8 × 43-1/4 × 19-5/8
9.9
Specifications