Daikin VRV - WII Service Manual page 43

Water cooled inverter series heat pump heat recovery-60hz r-410a
Hide thumbs Also See for VRV - WII:
Table of Contents

Advertisement

Specifications
Ceiling Mounted Duct Type
Model
1 Cooling Capacity
2 Heating Capacity
Casing / Color
Dimensions: (H×W×D)
Rows×Stages×FPI
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output
Fan
Air Flow Rate (H/L)
External Static Pressure
4
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight (Mass)
6 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
30
FXMQ30MVJU
Btu/h
30,000
Btu/h
34,000
Galvanized Steel Plate
in
15-3/8 × 28-3/8 × 27-1/8
3×16×13
ft²
1.95
D11/2D3AA1VE
Sirocco Fan
HP
0.21
cfm
690/565
in. Aq
0.66-0.43
Direct Drive
Microprocessor Thermostat
for Cooling and Heating
Glass Fiber
φ
in
3/8 (Flare Connection)
φ
in
5/8 (Flare Connection)
VP25
in
External Dia. 1-1/4
(
Internal Dia. 1
Lbs
dBA
45/41
Fuse, Thermal Fuse for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws.
1 Nominal cooling capacities are based on the following conditions:
Return air temperature: 80°FDB, 67°FWB
Outdoor temperature: 95°FDB
Equivalent ref. piping length: 25ft (Horizontal)
2 Nominal heating capacities are based on the following conditions:
Return air temperature: 70°FDB.
Outdoor temperature: 47°FDB, 43°FWB
Equivalent ref. piping length: 25ft (Horizontal)
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 External static pressure is changeable to change over the connectors inside electrical box, this pressure means
" High static pressure – Standard ".
5 Air filter is not standard accessory, but please mount it in the duct system of the suction side.
Select its colorimetric method (gravity method) 50% or more.
6 Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation,
these values are normally somewhat higher as a result of installation conditions.
FXMQ36MVJU
Galvanized Steel Plate
15-3/8 × 43-3/4 × 27-1/8
2D11/2D3AG1VE
Microprocessor Thermostat
for Cooling and Heating
5
φ
3/8 (Flare Connection)
φ
5/8 (Flare Connection)
External Dia. 1-1/4
)
(
99
Fuse, Thermal Fuse for Fan Motor
Electronic Expansion Valve
R-410A Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws.
36,000
40,000
3×16×13
3.43
Sirocco Fan
0.36
1,020/810
0.71-0.43
Direct Drive
Microprocessor Thermostat
Glass Fiber
5
VP25
)
Internal Dia. 1
139
45/41
Fuse, Thermal Fuse for Fan Motor
Electronic Expansion Valve
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation for
Fitting, Sealing Pads, Clamps, Screws.
C:3D042685
SiUS30-604
FXMQ48MVJU
48,000
54,000
Galvanized Steel Plate
15-3/8 × 43-3/4 × 27-1/8
3×16×13
3.43
2D11/2D3AF1VE
Sirocco Fan
0.58
1,270/1,020
1.0-0.72
Direct Drive
for Cooling and Heating
Glass Fiber
5
φ
3/8 (Flare Connection)
φ
5/8 (Flare Connection)
VP25
External Dia. 1-1/4
(
)
Internal Dia. 1
144
48/45
R-410A Series
Specifications

Hide quick links: