ELECTRICAL/MECHANICAL
SYMPTOM
No Power
No Circulation
G.F.C.I. Trip
Jet Surge
No Heat
Erratic Heat
Noisy Motor
No Ozone
Digital Top Side
No Longer Displays
Digital Temperature
Display is Erratic
or Flashing
H y d r O p O O l

GenerAl trOuBlesHOOtInG

POSSIbLE REASON(S)
– Breaker off at main panel or fuse out
– Improper wiring
– Fuse blown in control
– G.F.C.I. tripped
– Pump is not primed
– Air in waterline
– Impeller clogged
– Valves are closed
– Water level in spa is too low
– Skimmer obstructed or closed
– Short or ground in system
– Faulty G.F.C.I.
– Water level too low
– Blockage in lines
– Suction valve partly closed
– pressure switch not closing
– Hi Limit switch tripped
– Cartridge filter dirty
– Low water
– Faulty pressure switch
– Low Water
– Incorrectly adjusted pressure switch
– Faulty sensor
– Damaged or worn bearings
– Low voltage
– Low water level
– Frozen pump
– Clogged Impeller
– Not plugged in
– Broken bulb or expired bulb life
– Clogged ozone jet
– Improper connection
– Electrical brown-out
– Water temperature has exceeded set point – Decrease filter cycle
I n d u s t r I e s
CORRECTIvE ACTION
– Check panel
– Consult electrician
– Replace
– Reset
– G.F.C.I connected improperly
– Open drain bib
– Release air
– Access and clean
– Open valves
– Top up water
– Remove/Open
– As above-call Electrician or
Hydropool Dealer
– Add water
– Check valves and/or strainer
– Pull valve handle "up" all the way
– see TOPSIDE PANEL
– see TOPSIDE PANEL
– Clean & reinstall
– Top Up
– Adjust or replace
– Thermostat probe improperly installed
– Top Up
– Adjust
– Call your Electrician or Hydropool dealer.
– Check supply
– Top Up
– Thaw out
– Access and clean
– Remove obstruction with
"baby bottle" brush
– Unplug cable and re-connect
– Reboot control system