PURGE CYCLE
If your hot tub is equipped with a blower, the system will
automatically activate it for 30 seconds at the beginning of
each filter cycle.
STANDbY/DRAIN ASSIST
The standby/drain assist feature stops the system from
operating automatically, allowing for convenient filter
cartridge removal or for safe draining of the hot tub. To
put the system in standby, press and hold the 'Jets' pad for
5 seconds. All functions will turn off, but P1 low speed can
be activated (by pressing the
the spa. Press and hold the
the system to normal operation. The system automatically
shuts off P1 low speed after 3 hour, and exits 'Standby'
mode after 3 hours, resuming automatic operation.
If the heater is on when the 'Standby' mode is activated,
the pump will continue to operate for a 30 second cool
down period, during which time the SBY message will flash
on/off. See DRAINING YOUR HOT TUB - p. 47 for detailed
instructions.
MOOD LIGHTING
STANDARD MOOD LIGHTING
Press the
pad on the topside control to turn
the light on and off
LED MOOD LIGHTING
OPTIONAL – FACTORY INSTALLED
Press the
pad on the topside control to start the
selection of LED lighting modes. Pressing the
on/off within 3 seconds cycles through the various 'light
shows' . When the LED lighting is turned off for more than 5
seconds, then turned back on, the system will resume the
last 'light show' . For complete description of 'light shows',
see MOOD LIGHTING – p. 14
The system will automatically turn off the mood lighting
after 4 hours.
H y d r O p O O l
pad) to facilitate draining
pad for 5 seconds to return
pad
I n d u s t r I e s
bLOWER
OPTIONAL - FACTORY INSTALLED
Press this key to turn the blower on and off. The
system will automatically turn off the blower
after 15 minutes.
OzONATOR
OPTIONAL
The ozonator operates during FILTER CYCLES and CLEAN-UP
CYCLES only (starts 2 minutes after filter cycle begins)
FREEzE PROTECTION / SMART WINTER MODE
An onboard sensor continuously monitors the ambient
air temperature inside the control pack. If at anytime the
temperature drops below 55˚ F (13˚ C) the system activates
the Winter mode for the next 24 hours. In this mode, if the
pump has not been turned on in the last 2 hours (whether
manually or automatically), the system will automatically
activate P1 low speed for 1 minute to circulate warm water
through the plumbing. While the pump is operating in
this mode, the Filter indicator
on/off.
18
on the display will flash
Need help?
Do you have a question about the Hot Tub and is the answer not in the manual?