IMpOrtAnt eleCtrICAl sAFety InstruCtIOns

Safety comes first. When installing & using this electrical equipment, basic safety precautions should always be followed*
1 READ AND FOLLOW ALL INSTRUCTIONS
2 Electrical installation must be performed by qualified
persons only (electrician or equivalent).
3 Connect only to a dedicated circuit protected by a class
'A' two-pole ground fault circuit interrupter (GFCI)
4 Use copper conductors only!
5 The hot tub equipment and all electrical plugs, outlets
and lights within 1.5m (5ft) of the unit must be G.F.C.I
protected. Consult your electrician or local electrical
authority for further details.
6 A green colored terminal or a terminal marked "G", "GR",
"Ground", or "Grounding" is located inside the supply
terminal box or compartment. To reduce the risk of
electric shock, this terminal must be connected to the
grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to
the circuit conductors supplying the equipment.
7 At least two lugs marked "BONDING LUGS" are provided on
the external surface or on the inside of the supply terminal
box or compartment. To reduce the risk of electric
shock, connect the local common bonding grid in the
area of the hot tub to these terminals with an insulated
or bare copper conductor not smaller than No.6 AWG
(Canada/Europe) / No.8 AWG (USA).
8 All field installed metal components such as rails, ladders,
drains or other similar hardware within 3 m (10 ft) of the
hot tub shall be bonded to the equipment grounding bus
with copper conductors not smaller than No.6 AWG.
WIRE SIzE
NORTH AMERICA
• The minimum wire size for systems that require a 40A
GFCI is #8/3 c/w ground (also refered to as #8 gauge /
4 conductor).
• The minimum wire size for systems that require a 50A or
60A GFCI is #6/3 c/w ground (also refered to as #6 gauge
/ 4 conductor).
EUROPE
• The minimum wire size for European system is 2.5 mm
copper wire.
IMPORTANT NOTES:
• This guide is for standard installations where the wire
run is 15 m (50 ft.) or less. For longer wire runs, consult a
qualified electrician.
• This is the rated 'nameplate' amperage draw for
certification purposes. Actual amperage draw will vary
based on line voltage.
* AND READ THIS MANUAL THOROUGHLY bEFORE
PROCEEDING!
H y d r O p O O l
I n d u s t r I e s
G.F.C.I./r.C.d. ApplICAtIOn GuIde
NORTH AMERICA
HYDROPOOL SERIES
Silver – all
Gold – H200, 300, 400, 525, 600, 475, 575, 595, 638, 738, 700, 800
With blower system and/or Audio system option
Platinum – H200, 300, 475, 575, 595, 638, 738, 700, 800
With blower system and/or Audio or Audio/Video system option
Titanium – H700, 800, 1038
With blower system and/or Audio or Audio/Video system option
SERENITY/MILLENNIUM SERIES
Classic – S4
Limited – SM4000
With blower system and/or Audio system option
Classic – S5, S6, S7, S9, SM4000, 5000, 6000, 8000 40A
With blower system and/or Audio system option
Elite – S4, S5, S6, S7, S9, SM4000, 5000, 6000, 8000
Special Edition – S5
With blower system and/or Audio system option
Elite + – S5, S6, S9, SM4000, 6000, 8000
With blower system and/or Audio system option
EUROPE
HYDROPOOL AND SERENITY/MILLENIUM SERIES
All models
2
With blower system and/or Audio or Audio/Video system option
NORTH AMERICA AND EUROPE
AQUATRAINER
All models
10
FOr HydrOpOOl, serenIty,
AquAtrAIner 2004/05
40A
50A
50A
60A
60A
60A
30A
40A
50A
40A
50A
50A
60A
20A
20A
60A