spA COntrOl systeM – nOrtH AMerICA
plAtInuM & tItAnIuM serIes, serenIty/MIllenIuM elIte +
SYSTEM CONTROL HPEL2K3P, TOPSIDE PANEL TITANIUM - ML900/PLATINUM - ML700
INITIAL START-UP
Before applying voltage to power-up your hot tub, it is very
important that you understand the sequence of events that
occur when the system is activated in order that the pumps
can be primed efficiently and damage to the pumps can be
avoided.
At initial power-up, this display will appear,
and the system will show 4 sets of
numbers in succession (ie. 100 then 113
then 13 then 240). These numbers
represent the current software revision,
and the system input voltage.
After the initial software indicators are
shown, this display will appear. This display
is indicating that the system is in PUMP
PRIMING MODE. This mode will last for
4 to 5 minutes before automatically
exiting
Flashing
operation mode. You can also manually exit the PUMP
PRIMING MODE after the pumps are primed (see below).
While in this mode, the heater circuit is disabled to
allow the priming process to be completed without the
possibility of energizing the heater element during low flow
or no flow conditions. The system will not automatically
activate any of the functions, however, by pushing the
pads on the topside control, the pumps can be manually
activated
Definition: 'Priming' a pump is a term used to describe the
process in which air trapped in the plumbing and pump
wet-end (referred to as an 'air lock') is released, allowing
the pump to move water efficiently through the plumbing
system and to the jets.
H y d r O p O O l
and
entering
the
normal
I n d u s t r I e s
PUMP PRIMING MODE
As soon as PRIMING MODE is indicated
on the topside panel, push the left
to start Pump 1 in low speed, then again
to switch to high speed. Push the
center
Pump 2 and *Pump 3 respectively
Flashing
(*Titanium Series only). These are both
Pump.Icon(s)
single speed - high only. All of the pumps
will now be operating in high speed to facilitate priming.
See FILLING, CHECKING AND STARTING YOUR HOT TUB p. 15
for complete instructions on pump priming.
Once pump priming has been successfully completed, press
the
pads to turn off the pumps. Next, manually exit
PRIMING MODE by pressing either the
pad. If you do not manually exit Priming Mode, it will
automatically terminate after 4 to 5 minutes. Be sure that
the pumps have been primed before exiting this mode.
TEMPERATURE CONTROL
FUNCTIONALITY AND ADJUSTMENT
After you manually exit or the system automatically exits
PRIMING MODE, your hot tub will automatically heat to
the factory preset default temperature of 100˚F. The topside
panel will briefly show the default temperature, and then
the display will appear as follows:
Note that the water temperature is not
yet displayed, as the system requires
approximately 2 minutes of water flow
through the heater to determine
temperature. This is referred to as 'polling'
and is indicated on the display by the
Flashing
icon. After 2 minutes the display
Pump.1.Low.Speed.Icon
will show the current measured water
temperature.
Press the
temperature to the desired setting. The
icon will appear on the display
indicating that the heater has been
activated.
Flashing
Pump.1.Low.speed.Icon
The system automatically activates Pump 1 low speed every
30 minutes for at least 2 minutes. After 2 minutes, the spa
water temperature is determined. At this point, if the water
temperature is lower than the set temperature, P1 will
continue to run and the
The heater will operate until the water temperature reaches
the set temperature point, after which, both the heater and
Pump 1 low will automatically turn off.

pad
pad and right
pad to start
pad or the
pad to increase the
icon will appear on the display.