Hydropool Hot Tub Owner's Manual page 23

Hide thumbs Also See for Hot Tub:
Table of Contents

Advertisement

TO CHECK/CHANGE THE SET TEMPERATURE
The last measured temperature is constantly
displayed on the topside control. When either of these pads
is pressed once, the display will show the set temperature.
Press either pad a second time to increase or decrease the
set temperature. After 3 seconds the display will once again
show the last measured temperature.
The temperature can be adjusted from 80˚F to 104˚F in
1˚ increments
PUMPS / JETS FUNCTION
from left to right on topside control – P1, P2, *P3
(*Titanium series only)
PUMP 1 (P1)
1 st press – turns on low speed – the P1 icon
2 nd press – turns on high speed – the P1 icon
3 rd press – turns off pump
When P1 low is already operating, the 1 st press of the P1
pad puts the pump directly into high speed.
Low speed P1 starts automatically every 30 minutes to
measure water temperature (in STANDARD Mode only – see
MODE FUNCTION), when a filter cycle is activated, or when
a freeze condition is detected.
When P2, P3 or the blower is manually activated, P1 low
speed is automatically activated and operates until the
pump(s) or blower time out. If P2, P3 or the blower is turned
on even briefly, and then turned back off, P1 low will
operate for a minimum of 2 minutes.
PUMP 2 (P2)
1 st press – turns on high speed – the P2 icon
2 nd press – turns off pump
PUMP 3 (P3) – TITANIUM SERIES ONLY
1 st press – turns on high speed – the P3 icon
2 nd press – turns off pump
PUMPS AUTOMATIC TIME-OUT
P1 high speed, P2 & P3 – 15 minutes
P1 low speed – 4 hours.
H y d r O p O O l
I n d u s t r I e s
CLEAN-UP CYCLES
The Clean-up Cycle begins 30 minutes after the pump(s)
or blower have been turned off or have automatically
timed-out. P1 low speed and the ozonator (optional) will
operate for one hour.
SETTING THE SYSTEM CLOCK TIME
The
start-up. This reminder will disappear once the clock time
is programmed.
Press
To set the hour: Press
time by 1 hour.
Press
spins slowly
To set minutes: Press
spins faster
time by 1 minute.
– no icon displayed
when P1 is off
Press the
programming mode (see below)
OR
Press the
During normal operation, pressing the
the current time for 3 seconds.
FILTER CYCLES
Once the system clock time has been programmed, the
system will automatically activate P1 low speed to filter the
water for 2 hours twice each day. During the filter cycle, the
display will show FILTER 1 or FILTER 2.
FACTORY PRESET DEFAULT
'FILTER 1' the system automatically activates P1 low to
spins fast
operate from 8 AM to 10 AMThe filter 1 LED indicator will
– no icon displayed
light during filter cycle 1 operation.
when P2 is off.
'FILTER 2' the system automatically activates P1 low to
operate from 8 PM to 10 PM The filter 2 LED indicator will
light during filter cycle 2 operation.
spins fast
– no icon displayed
when P3 is off.
3
flashes on the topside control display upon initial
then
to enter programming mode.
or
- each press changes the
to enter, and to continue to set minutes.
or
- each press changes the
pad again to continue to the filter cycle
pad to exit programming mode.
pad will display