5.16 Transfer Ass'y
1. Before you remove the Transfer Ass'y, you should
remove:
- Rear Cover (see page 5-2)
- Side Cover (LH, RH) (see page 5-3)
- Scanner Ass'y (see page 5-5)
- Front Cover (see page 5-4)
- Middle Cover (see page 5-11)
- LSU (see page 5-18)
2. Remove the three screws securing the Transfer Earth
and remove it.
Transfer
Earth
WorkCentre PE16
Disassembly and Reassembly
3. Unplug the PTL Holder connector, then remove the
PTL Holder and PTL Lens, as shown below.
PTL
PTL
Lens
Holder
4. Unlatch the Bushing and remove it. Then lift the
Transfer Roller out, as shown below.
Transfer
Roller
Bushing