Disassembly and Reassembly
5.14 LSU
1. Before you remove the LSU, you should remove:
- Rear Cover (see page 5-2)
- Side Cover (LH, RH) (see page 5-3)
- Scanner Ass'y (see page 5-5)
- Front Cover (see page 5-4)
- Middle Cover (see page 5-11)
2. Unplug the two connectors.
5.15 Drive Ass'y
1. Before you remove the Drive Ass'y, you should
remove:
- Rear Cover (see page 5-2)
- Side Cover (LH) (see page 5-3)
2. Remove the six screws securing the Drive Ass'y.
Service Manual
5-18
July 2003
3. Remove the three screws securing the LSU and
remove it.
3. Take out the Drive Ass'y, then unplug the connector
from the Main PBA, as shown below.