9. Front Panel Interface
Group sum displays
Some of the PLM's parameters display two values instead of one. The parameters concerned are:
▸
Module > Gain
▸
Module > Delay
▸
Module > Limiters > MaxRMS Level
▸
Module > Limiters > MaxPeak Level
For each of these parameters, the primary value, which is adjusted by the rotary control, is shown above the
Group Sum value, which is displayed in brackets.
The Group Sum parameter value will initially be the same as the primary value. However, as Lake Processing
Modules may belong to Groups (possibly spanning mutilple Frames), and these parameters may be adjusted
in the Lake Controller software for the whole Group, it is useful for the effect of this additional Group
adjustment to be taken into account. The Group Sum parameter value is effectively the sum of the individual
Module value plus any gain, delay, etc. that has been applied to the whole Group.
Menu structure
From the top page of the menu system, the following seven submenus are available:
▸
Module
▸
Input configuration
▸
Attenuation
▸
Frame
▸
Frame Preset
▸
Load Monitoring features
▸
Dante
9.13.2 Module submenu
This submenu is selected by pressing soft button 2, named Module from the menu top page.
Menu
Module
Amp Gain
Gain
Limiters
Delay
Polarity
Mute
Figure 9.13.2: Module menu view
The options available are as follows:
9.13.2.1 Gain
This option is selected by pressing soft button 2 (Gain) from Menu è Module.