PLM 10000Q Powered Loudspeaker Management system
The▸ two-▸ input,▸ four-▸ output▸ PLM▸ 10000Q▸ seamlessly▸ integrates▸ ▸
networked▸digital▸signal▸distribution,▸drive▸processing,▸power▸ampli-
fication,▸and▸load▸verification▸plus▸performance▸monitoring▸in▸a▸single▸
hardware▸ unit▸ and▸ unified▸ software▸ controller.▸ This▸ new▸ approach,▸
Lab.gruppen Technology
▸ ▸ 2350▸W▸per▸channel▸@▸2▸ohms**
▸ ▸ 2300▸W▸per▸channel▸@▸4▸ohms**
▸ ▸ 2U▸chassis▸weighing▸only▸13.5▸kg▸(30▸lbs)
▸ ▸ Class▸TD
®
▸output▸stage
▸ ▸ Regulated▸Switch▸Mode▸Power▸Supply▸(R.SMPS
▸ ▸ Copper-finned▸ Intercooler
devices
▸ ▸ Full▸suite▸of▸protection▸and▸fault▸monitoring▸features
▸ ▸ Comprehensive▸loudspeaker▸preset▸database
▸ ▸ LoadLibrary
▸load▸"Fingerprint"▸(identity▸and▸characteristics)▸data
▸ ▸ Comprehensive▸ LoadSmart
continuous▸loudspeaker▸performance▸monitoring
▸ ▸ Dante
▸low-latency▸digital▸network▸included▸as▸standard▸
Lake Processing Technology
▸ ▸ Raised▸Cosine▸Equalization
▸ ▸ Linear▸phase▸and▸classical▸crossovers
▸ ▸ LimiterMax
▸–▸peak▸and▸RMS▸limiters
▸ ▸ Iso-Float
▸ground▸isolation
▸ ▸ Super▸Module▸capability
)
▸ with▸ transverse-mounted▸ output▸
®
▸ load▸ verification▸ and▸ SpeakerSafe
PLM
Series: Powered Loudspeaker Management
designated▸Powered▸Loudspeaker▸Management▸(PLM),▸is▸a▸cohesive▸
blend▸of▸Lake
▸Processing▸and▸Lab.gruppen▸power.▸As▸a▸complete▸
®
system,▸ the▸ PLM▸ 10000Q▸ affords▸ significant▸ benefits▸ when▸ com-
pared▸to▸conventional▸approaches▸utilizing▸separate▸components.
▸ ▸ Fully▸ compatible▸ with▸ Dolby▸ Lake▸ Processor,▸ Lake▸ Contour
and▸Lake▸Mesa▸Quad▸EQ
▸ ▸ Primary▸and▸secondary▸network▸connections▸(for▸daisy▸chaining▸or▸
system▸redundancy)
▸ ▸ Digitally▸controlled▸"amplifier▸gain"▸adjustable▸in▸0.1▸dB▸steps▸from▸
22▸to▸44▸dB
▸ ▸ Digital▸output▸attenuation▸in▸0.25▸dB▸steps▸from▸-inf▸to▸0▸dB
▸ ▸ Binding▸ post▸ or▸ Neutrik
output▸connectors▸
▸ ▸ Digitally▸ implemented,▸ zero-overshoot▸ Inter-Sample▸ Voltage▸ Peak▸
Limiting▸(ISVPL
)▸adjustable▸in▸0.1▸V▸steps▸from▸17.8▸to▸153▸V▸
▸ ▸ Power▸Average▸Limiter▸(PAL)▸
▸ ▸ High-brightness▸front-panel▸LCD▸display
▸ ▸ Moisture▸resistant▸silicone▸touchpad▸for▸front-panel▸display▸mode▸
selection▸and▸menu▸navigation
**▸▸More▸power▸available▸when▸driven▸asymmetrically.
▸ ▸ Integration▸ of▸ third▸ party▸ frequency▸ measurement▸ and▸ analysis▸
system▸via▸the▸Lake▸Analyzer▸Bridge
▸ ▸ Analog▸and▸AES▸digital▸inputs▸with▸loop-thru▸outputs
▸ ▸ Auto-select▸input▸router▸for▸all▸inputs▸with▸user▸definable▸priorities▸
Technical Data
▸and▸Mesa▸Parametic▸EQ
▸devices
▸ Speakon
▸ (1▸ x▸ NLT8,▸ 2▸ x▸ NLT4)▸ power▸
®
®
,▸

Advertisement

loading
Need help?

Need help?

Do you have a question about the PLM 10000Q and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lab.gruppen PLM 10000Q

  • Page 1 Technical Data Series: Powered Loudspeaker Management ™ ™ PLM 10000Q designated▸Powered▸Loudspeaker▸Management▸(PLM),▸is▸a▸cohesive▸ PLM 10000Q Powered Loudspeaker Management system The▸ two-▸ input,▸ four-▸ output▸ PLM▸ 10000Q▸ seamlessly▸ integrates▸ ▸ blend▸of▸Lake ▸Processing▸and▸Lab.gruppen▸power.▸As▸a▸complete▸ ® networked▸digital▸signal▸distribution,▸drive▸processing,▸power▸ampli- system,▸ the▸ PLM▸ 10000Q▸ affords▸ significant▸ benefits▸ when▸ com- fication,▸and▸load▸verification▸plus▸performance▸monitoring▸in▸a▸single▸...
  • Page 2 Powered Loudspeaker Management: Technology Overview Power Amplifier speaker▸ Management▸ system.▸ In▸ addition▸ to▸ controlling▸ all▸ ▸ parameters▸ of▸ standard▸ Lake▸ Processing▸ (therefore▸ appropriate▸ for▸ Although▸ based▸ on▸ technology▸ in▸ Lab.gruppen’s▸ road-proven▸ ▸ FP+▸Series,▸the▸amplifier▸platform▸in▸the▸PLM▸10000Q▸Powered▸Loud- use▸with▸Dolby▸Lake▸Processors),▸all▸new▸versions▸provide▸control▸and▸ speaker▸ Management▸ system▸ incorporates▸ further▸ enhancements▸...
  • Page 3 4+/- CH 4+/- 2+/- CH 4+/- Must be grounded/earthed Ser. N:o Removed! Made in Sweden The PLM 10000Q▸ is▸ available▸ with▸ either▸ binding▸ posts▸ or▸ an▸ “embedded▸ patch▸ panel”▸ with▸ Neutrik▸ Speakon▸ connectors▸ (2▸ x▸ NLT4▸ and▸ 1▸x▸NLT8).▸Common▸connectors▸include;▸2▸x▸analog▸input▸XLR▸with▸switchable▸Iso-Float,▸2▸channels▸of▸AES/EBU▸with▸link-through▸capability▸ for▸daisy▸chaining,▸2▸x▸EtherCon ▸for▸linking▸or▸redundancy.▸A▸32▸amp▸PowerCon ▸connector▸is▸used▸for▸mains▸supply. ®...
  • Page 4 ▸ SpeakerSafe▸and▸ISVPL▸are▸trademarks▸of▸Lab.gruppen▸AB.▸Dolby▸and▸the▸double-D▸symbol▸are▸registered▸trademarks▸of▸Dolby▸Laboratories.▸Contour,▸Mesa▸Quad▸EQ,▸Mesa▸Parametric▸EQ,▸Raised▸▸ ▸ Cosine▸Equalization,▸LimiterMax▸and▸Iso-Float▸are▸trademarks▸of▸Dolby▸Laboratories.▸▸Audinate▸is▸a▸registered▸trademark▸of▸Audinate▸Pty▸Ltd.▸Dante▸and▸Zen▸are▸trademarks▸of▸Audinate▸Pty▸Ltd.All▸▸ ▸ other▸trademarks▸remain▸the▸property▸of▸their▸respective▸owners. ▸ Copyright © 2009 Lab.gruppen AB. All rights reserved. L a b . g r u p p e n a b ▸ S w e d e n i n t e r n a t i o n a L c o n t a c t ▸ i n f o @ L a b g r u p p e n . c o m u S &...