3.6.2

Startup for Windows Systems

One Instance. To start up one instance of CCI on a Windows system:
1. Modify \WINNT\system32\drivers\etc\services to register the port name/number
(service) of the configuration definition file. Make the port name/number the same on
all servers: horcm
2. If you want HORCM to start automatically each time the system starts up, add
\HORCM\etc\horcmstart to the system automatic start-up file (e.g., \autoexec.bat).
3. Execute the horcmstart script manually to start CCI: D:\HORCM\etc> horcmstart
4. Set the log directory (HORCC_LOG) in the command execution environment as needed.
5. If you want to perform Hitachi TrueCopy operations, do not set the HORCC_MRCF
environment variable. If you want to perform ShadowImage operations, set the
HORCC_MRCF environment variable for the HORCM execution environment:
D:\HORCM\etc> set HORCC_MRCF=1
D:\HORCM\etc> pairdisplay -g xxxx
Two Instances. To start up two instances of CCI on a Windows system:
1. Modify \WINNT\system32\drivers\etc\services to register the port name/number
(service) of the configuration definition files. Make sure that the port name/number is
different for each instance:
horcm0
horcm1
2. If you want HORCM to start automatically each time the system starts up, add
\HORCM\etc\horcmstart 0 1 to the system automatic start-up file (e.g., \autoexec.bat).
3. Execute the horcmstart script manually to start CCI: D:\HORCM\etc> horcmstart 0 1
4. Set an instance number to the environment which executes a command:
D:\HORCM\etc> set HORCMINST=X
5. Set the log directory (HORCC_LOG) in the command execution environment as needed.
6. If you want to perform Hitachi TrueCopy operations, do not set the HORCC_MRCF
environment variable. If you want to perform ShadowImage operations, set the
HORCC_MRCF environment variable for the HORCM execution environment:
D:\HORCM\etc> set HORCC_MRCF=1
D:\HORCM\etc> pairdisplay -g xxxx
xxxxx/udp
xxxxx/udp
xxxxx = the port name/number of horcm0.conf
xxxxx/udp
xxxxx = the port name/number of horcm1.conf
Hitachi Command Control Interface (CCI) User and Reference Guide
xxxxx = the port name/number of horcm.conf
xxxx = group name
X = instance number = 0 or 1
xxxx = group name