New installation. To install the CCI software on an OpenVMS
1. Insert and mount the provided CD or diskette.
2. Execute the following command:
$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -
_$ /destination=SYS$POSIX_ROOT:[000000]
3. Verify installation of the proper version using the raidqry command:
$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
4. Follow the requirements and restrictions in section 3.5 for porting for OpenVMS.
Version update. To update the CCI software version on an OpenVMS
1. Perform the update after making sure that HORCM is not in operation:
$horcmshutdown for one HORCM instance
$horcmshutdown 0 1 for two HORCM instances
When a command is being used in interactive mode, terminate it using the "-q" option.
2. Insert and mount the provided CD or diskette.
3. Execute the following command:
$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG
4. Verify installation of the proper version using the raidqry command:
$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/02
Usage: raidqry [options]
5. Follow the requirements and restrictions in section 3.5 for porting for OpenVMS.
132
Chapter 3 Preparing for CCI Operations
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists