Installing An Optional Mini-Pci-X Enablement Card - Lenovo ThinkServer TS100 User Manual

Types 6431, 6432, 6433, and 6434
Hide thumbs Also See for ThinkServer TS100:
Table of Contents

Advertisement

10. Replace the hard disk drive fan assembly:
11. Reconnect the hard disk drive fan assembly cable to the system board.
12. Rotate the drive cage back into the server until it stops; then, press and hold
13. Reinstall the hard disk drives.
14. Install the side cover (see "Reinstalling the side cover" on page 53).
15. Lock the side cover.
16. Reconnect the external cables and power cords; then, turn on the attached

Installing an optional mini-PCI-X enablement card

To install an optional mini-PCI-X enablement card, complete the following steps:
1. Read the safety information that begins on page v and "Installation guidelines"
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 23).
4. Touch the static-protective package that contains the mini-PCI-X enablement
Note: The drive cage should be in the open position. This illustration shows it
in the closed position.
8. Press the ServeRAID-MR10i SAS/SATA controller firmly into the connector on
the system board.
9. Take the other end of the signal cable that is attached to the drive backplane
section for drive bays 0 through 3 (as labeled on the front of the drive cage)
and connect it to the connector that is closest to the battery on the
ServeRAID-MR10i SAS/SATA controller. If drives are installed in drive bays 4
through 7 (as labeled on the front of the drive cage), take the other end of the
signal cable that is attached to drive backplane section for drive bays 4
through 7 and connect it to the connector that is farthest from the battery on
the ServeRAID-MR10i SAS/SATA controller.
a. Insert the hard disk drive fan assembly retaining tab over the right edge of
the hard disk drive backplane; then, rotate the hard disk drive fan
assembly toward the backplane. Do not fully close the hard disk drive fan
assembly.
b. Route the signal cables and power cable through the slot on the edge of
the hard disk drive fan assembly. Make sure that the cables will not be
pinched between the hard disk drive fan assembly and the hard disk drive
backplane when the assembly is installed.
c. Rotate the hard disk drive fan assembly toward the backplane until the
release tabs are fully engaged and snap into place.
the retaining tab on top of the drive cage while you rotate the drive cage into
the chassis until it is in the closed position.
Note: Before you continue, check all internal power cables to make sure that
they are connected to the system board and other optional devices.
devices and turn on the server.
on page 19.
and external cables.
card to any unpainted surface on the outside of the server; then, remove
mini-PCI-X enablement card from the package.
Chapter 2. Installing optional devices
45

Advertisement

Table of Contents
loading

Table of Contents