System Alarm; Set Menu; System Set Menu - Raisecom RC3000 PCM User Manual

Pcm multi-service multiplexer
Table of Contents

Advertisement

2E1 Alarm:No Alarm
Alarm Query Command:1-2, Menu Display:M, Return:Q
Note: E1 interface alarms include: LOS, AIS, LOF, RAL, LOMF, CRC and CRC LOMF
Optical interface alarms include: Optical LOS, Frame LOF , E-3 ERROR and E-6
ERROR
Alarms include: E1 interface alarms and line-board alarms. There are E1 interface
alarms only when that E1 interface is used, so are line-board alarms.

10.7.2. System Alarm

In alarm query menu press number key 1 there will be system alarm information:
System Alarm:
EEPROM Block:
User Board Com: 1:Success 3:Success
Line Board Com: Fail
Temp Sensor:
Fans:
Alarm Query Command:1-2, Menu Display:M, Return:Q

10.8. Set menu

In main menu press number key 5 and there will be set menu:
1.System Set
2.Cross Set
Set Command:1-2, Menu Display:M, Return:Q

10.9. System Set menu

In set menu press number key 1 there will be system set menu:
1.ID Set
2.Baud Rate Set
3.Line Board Set
4.E1 Set
5.Clock Set
6.Net Topology Set
7.Alarm Sound Set
8.User Board Set
9.DCD and RTS of V35V24 Board with Alarm Set
System Set Command:1-9, Menu Display:M, Return:Q
Main:Correct(T T T)
2M Block:Correct(T T T) Version:Correct(T T T)
Normal 30
Normal
Command:
63
Raisecom Technology Co., Ltd
Command:
E1 Block:Correct(T T T)
Command::
Command:

Hide quick links: