How To Use; Introduction Of The Front Panel; Power Indicator; Alarm Indicator - Raisecom RC801 User Manual

Rc801/803/805-240b series 8e1 fiber-optic multiplexer
Hide thumbs Also See for RC801:
Table of Contents

Advertisement

4.1. Introduction of the Front Panel

GL
Power
LOS on E1

4.1.1. Power indicator

PWR (green): On, when built-in power is working properly

4.1.2. Alarm indicator

Alarm indicators of both local and remote side can be displayed. The L row indicates "local".
The R row indicates "Remote".
General alarm:
GL general alarm indicator (red): Any of alarm generated will make GL general alarm
indicator "on".
LOS for E1 link
LOS1~ 8 E1 link (red): when receiving signals of any E1 channel is lost, alarm indicator
turns red.
Alarm of optical port:
LOS link loss alarm (red): When receiving signals are lost, the alarm indicator turns on.
LOF frame synchronization loss alarm (red): When optical receiving frames lose
synchronization, the alarm indicator turns on.
E-3 bit error alarm (red): ON, when the receiving bit error rate exceeds 10
E-6 bit error alarm (yellow): ON, when the receiving bit error rate exceeds 10

4.1.3. DIP-switch SW1 Setup: All OFF by Default

DIP-Switch SW1 on the front panel is used for setting of
loop-back test and saving the configurations
st
th
1
~ 4
: Loop-back
st
1
bit
OFF

4. How to use

Dip-switch
Figure1: Sketch of the front panel of RC800-240B
nd
2
bit
OFF
Function Button
rd
th
3
bit
4
OFF
OFF
6
Raisecom Technology Co., Ltd
Optical Interface
Optical Alarm
OFF
ON
1 2 3 4 5 6
bit
Loop-back
No
loop-back
NM Interface
-3
.
-6
.

Advertisement

Table of Contents
loading

Table of Contents