4.1. Introduction of the Front Panel
GL
Power
LOS on E1
4.1.1. Power indicator
PWR (green): On, when built-in power is working properly
4.1.2. Alarm indicator
Alarm indicators of both local and remote side can be displayed. The L row indicates "local".
The R row indicates "Remote".
•
General alarm:
GL general alarm indicator (red): Any of alarm generated will make GL general alarm
indicator "on".
•
LOS for E1 link
LOS1~ 8 E1 link (red): when receiving signals of any E1 channel is lost, alarm indicator
turns red.
Alarm of optical port:
LOS link loss alarm (red): When receiving signals are lost, the alarm indicator turns on.
LOF frame synchronization loss alarm (red): When optical receiving frames lose
synchronization, the alarm indicator turns on.
E-3 bit error alarm (red): ON, when the receiving bit error rate exceeds 10
E-6 bit error alarm (yellow): ON, when the receiving bit error rate exceeds 10
4.1.3. DIP-switch SW1 Setup: All OFF by Default
DIP-Switch SW1 on the front panel is used for setting of
loop-back test and saving the configurations