Cross Set; Create Group Cross - Raisecom RC3000 PCM User Manual

Pcm multi-service multiplexer
Table of Contents

Advertisement

10.16.1.

Cross Set

In cross set menu press number key 1 to configure the cross connect:
Input Group Number (1-8):
First input the cross group number:
First Channel:
There are two parts of configured data for each channel: a group number and a channel
number (there must be space between the two numbers) such as:
deleting the cross connection of this channel.
next channel (for unfinished entering you cannot start to configure the next channel and
the invalid data will be discarded).
Second Channel:
Press ENTER to confirm configuration (or skip that channel's configuration and the old
value will be reserved), press E key to finish configuration, and ESC to cancel
configuration.
10.16.2.

Create Group Cross

In cross set menu press number key 2 to create group cross:
Group No. for Time Slot Out:
The entering must be a number from 1 to 8, press ENTER to confirm and start the
configuration of next item. The system will check the entered number, if invalid it will be
discard; if valid there will be next item configuration.
Time Slot Start No. for Time Slot Out:
The entering must be a number from 1 to 31, press ENTER to confirm and start the
configuration of next item. The system will check the entered number; if invalid it will be
discard; if valid there will be next item configuration.
Group No. for Time Slot In:
The entering must be a number from 1 to 8, press ENTER to confirm and start the
configuration of next item. The system will check the entered number; if invalid it will be
discard; if valid there will be next item configuration.
Time Slot Start No. for Time Slot In:
The entering must be a number from 1 to 31, press ENTER to confirm and start the
configuration of next item. The system will check the entered number; if invalid it will be
discard; if valid there will be next item configuration.
Time Slot Number for Create Cross:
The entering must be a number from 1 to 31, press ENTER to confirm and start the
configuration of next item. The system will check the entered number; if invalid it will be
discard; if valid there will be next item configuration.
Create Mode:Uni-direction
In this statu use → to change the configured value: Uni-direction & Bi-direction, press
ENTER to confirm and start the configuration of next item.
Deal Mode for Old Relation Data:Retain
Raisecom Technology Co., Ltd
Press ENTER for the configuration of the
79
1 1, 0 0 indicates