Power Unit Redundancy Sensor; Table 17: Power Unit Redundancy Sensors Typical Characteristics - Intel S1400FP Manual

Epsd platform based on intel xeon processor e5 4600/2600/2400/1600/1400 product families
Table of Contents

Advertisement

Power Subsystems
System Event Log Troubleshooting Guide for EPSD Platforms Based on Intel
Sensor Specific Offset
Hex
Description
05h
Soft Power Control
Failure
06h
Power Unit Failure
4.3.2

Power Unit Redundancy Sensor

This sensor is enabled on the systems that support redundant power supplies. When a system has AC applied or if it loses
redundancy of the power supplies, a message will get logged into the SEL.
36
Description
Generally means power good was lost in
the system, causing a shutdown.
Power subsystem experienced a failure.

Table 17: Power Unit Redundancy Sensors Typical Characteristics

Byte
Field
11
Sensor Type
09h = Power Unit
12
Sensor Number
02h
13
Event Direction and
[7] Event direction
Event Type
[6:0] Event Type = 0Bh (Generic Discrete)
[7:6] – 00b = Unspecified Event Data 2
14
Event Data 1
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset as described in Table 18
15
Event Data 2
Not used
16
Event Data 3
Not used
Intel order number G90620-002
Xeon
Processor E5 4600/2600/2400/1600/1400 Product Families
®
®
This could be cause by the power supply subsystem or system
components.
1.
Verify all power cables and adapters are connected properly (AC
cables as well as the cables between the PSU and system
components).
2.
Cross test the PSU if possible.
3.
Replace the power subsystem.
Indicates a power supply failed.
1.
Remove and reapply AC power.
2.
If the power supply still fails, replace it.
Description
0b = Assertion Event
1b = Deassertion Event
Next Steps
Revision 1.1

Hide quick links:

Advertisement

Table of Contents
loading