Table 44: Discrete Thermal Sensors Typical Characteristics; Table 45: Discrete Thermal Sensors - Next Steps - Intel S1400FP Manual

Epsd platform based on intel xeon processor e5 4600/2600/2400/1600/1400 product families
Table of Contents

Advertisement

Cooling Subsystem
System Event Log Troubleshooting Guide for EPSD Platforms Based on Intel
Sensor
Sensor Name
Number
0Dh
SSB Thermal Trip
90h
P1 VRD Hot
91h
P2 VRD Hot
92h
P3 VRD Hot
93h
P4 VRD Hot
94h
P1 Mem01 VRD Hot
95h
P1 Mem23 VRD Hot
96h
P2 Mem01 VRD Hot
56

Table 44: Discrete Thermal Sensors Typical Characteristics

Byte
Field
11
Sensor Type
12
Sensor Number
13
Event Direction and
Event Type
14
Event Data 1
15
Event Data 2
16
Event Data 3
Table 45: Discrete Thermal Sensors – Next Steps
Event
Event Trigger Offset
Type
Hex
Description
03h
01h
State Asserted
05h
01h
Limit Exceeded
Intel order number G90620-002
Xeon
Processor E5 4600/2600/2400/1600/1400 Product Families
®
®
Description
01h = Temperature
See Table 45
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = See Table 45
[7:6] – 00b = Unspecified Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset as described in Table 45
Not used
Not used
Description
South Side Bridge (SSB) overheated
Processor 1 voltage regulator overheated
Processor 2 voltage regulator overheated
Processor 3 voltage regulator overheated
Processor 4 voltage regulator overheated
Processor 1 Memory 0/1 voltage regulator
overheated
Processor 1 Memory 2/3 voltage regulator
overheated
Processor 2 Memory 0/1 voltage regulator
overheated
Next Steps
1.
Check for clear and unobstructed
airflow into and out of the chassis.
2.
Ensure the SDR is programmed and
correct chassis has been selected.
3.
Ensure there are no fan failures.
4.
Ensure the air used for cooling the
system is within the thermal
specifications for the system (typically
below 35° C).
Revision 1.1